Online UPS  



Model: HP8900 Series (3:3)
10kVA~200kVA






Application field:
Centralized server center, network control center, computing center

Features & Benefits:
Three phases in, three phases out
True on-line dual conversion design
SPWM
IGBT inverter design
UPS can carry 100% non-balance load
Extendable run time
Generator compatible
Cold start
Load/battery capacity display
With Isolation transformer
Overload, on-line, battery status LED/LCD display.
Advanced Battery Management
RS-232
Optional SNMP card


specifications

Model
HP8910
HP8915
HP8920
HP8930
HP8940
HP8950
HP8960
HP8980
Rating
10KVA
15KVA
20KVA
30KVA
40KVA
50KVA
60KVA
80KVA
Operating Mode
and Principle
True on-Line, Static Bypass(Uninterruptible Switch), Dual Conversion, Output Galvanic Isolation
AC Input
Phase
3 Phases + N + G
Voltage
208/380V ± 25%
Frequency
50/60Hz ± 5%
P.F.
0.92
Soft Stat
0~100% 5s
Bypass
Input
Phase
3 phases + N + G
Voltage
208/380V ± 25%
Frequency
50/60Hz ± 5%
Transfer Time
0ms,Inverter/Bypass (Overload)
DC System
Volage
192/360V (Rated Voltage)
Volage
216/405V (Float Charge Voltage)
Volage
168/315V (Shutdown Voltage)
Current
25
38
51
76
101
126
152
203
Current
1A ~ 30A (Adjustable, Charge Current)
AC Output
Phase
3Phases + N + G
Voltage
120;208/380V ± 1%(Stable Load); 120;208/380V ± 5%(Fluctuated Load)
Fequency
50~60Hz ± 0.05% ( Battery Mode)
P.F.
0.8-0.85
Wave
True Sine Wave
Distortion
Total Harmonic Distortion: <3%(Linear Load); <5%(Non-Linear Load)
Times
Transient Recovery Time:<10 m
Overload
125% for 10 Minutes; 150% for 1Minute
Cooling
Forced Wind
System
Efficiency
91%
91%
92%
92%
93%
93%
93%
95%
Interface
RS232;SNMP (Optional)
Temperature
0~ 40 ? (Operating)
Humidity
30~90%
Optional
Isolation Transformer
Harmonic Suppression Filter
Up to six Parallel Modules
Noise(db)
48-55
53-65
55-65
Dimension(mm)
650×700×13507
760×720×1450
60×850×1500
1100×860×1680

Model
HP89100
HP89120
HP89140
HP89160
HP89200
HP89300
HP89400
Rating
100KVA
120KVA
140KV
16.0KV
200KVA
300KVA
400KVA
Operating Mode and Principle
True on-Line, Static Bypass(Uninterruptible Switch), Dual Conversion, Output Galvanic Isolation
AC Input
Phase
3 Phases + N + G
Voltage
380V ± 25%
Frequency
50/60Hz ± 5%
P.F.
0.92
Soft Stat
0~100% 5s
Bypass Input
Phase
3 phases + N + G
Voltage
380V ± 25%
Frequency
50/60Hz ± 5%
Transfer Time
0ms,Inverter/Bypass (Overload)
DC System
Volage
360V (Rated Voltage)
405V (Float Charge Voltage)
315V (Shutdown Voltage)
Current
253
305
355
405
550
760
1015
Current
1A ~ 30A (Adjustable, Charge Current)
AC Output
Phase
3Phases + N + G
Voltage
380V ± 1%(Stable Load); 380V ± 5%(Fluctuated Load)
Fequency
50~60Hz ± 0.05% ( Battery Mode)
P.F.
=0.8
Wave
True Sine Wave
Distortion
Total Harmonic Distortion: <3%(Linear Load); <5%(Non-Linear Load)
Time
Transient Recovery Time:<10 ms
Overload
125% for 10 Minutes; 150% for 1Minute
Cooling
125% for 10 Minutes; 150% for 1Minute
System
Efficiency
95%
95%
95%
95%
95%
95%
95%
Interface
RS232, SNMP
Temperature
0~ 40 ? (Operating)
Humidity
30~90%
Optional
Isolation Transformer
Harmonic Suppression Filter
Up to six Parallel Modules
Noise(db)
55-65
60-65
65-70
Dimension(mm)
1100×860×1680
1500×1250×1800
1800×1250×1800